China Best Sales Nhf130 Hydraulic Safety Coupling with Flange flange coupling

Product Description

NHF Hydraulic Safety Coupling With Flange

Description of NHF Hydraulic Safety Coupling With Flange
1.Simple and convenient assembly and disassembly;
2.No keyway and thrust ring are required on the shaft;
3.The stress on the entire contact surface is relatively uniform, and the stress concentration is not obvious;
4.When the vibration load of the shaft system changes, the shaft will not be worn;
5.The position of the coupling on the shaft is easy to ensure, and the connection accuracy is high;
6.Can be used repeatedly, with high interchangeability.

Dimensions of NHF Hydraulic Safety Coupling With Flange

 

d

D

L

L1

Df

Dc

R

t

n

ds

Mt

Mass

mm

mm

mm

mm

mm

mm

mm

mm

 

mm

kNm

kg

NHF100

100

170

215

40

265

230

9

21

8

19

26

26

NHF110

110

186

235

45

295

255

10

23

8

21

35

34

NHF120

120

202

250

50

315

275

11

25

8

23

46

42

NHF130

130

218

270

55

340

295

11

27

8

25

58

52

NHF140

140

234

290

60

355

310

12

29

10

24

72

64

NHF150

150

250

300

60

380

335

13

31

10

26

89

75

NHF160

160

266

320

65

405

355

14

33

10

28

108

91

NHF170

170

282

340

70

430

375

15

35

10

30

130

108

NHF180

180

298

355

75

440

390

15

37

12

29

154

124

NHF190

190

314

375

80

465

410

16

39

12

30

181

145

NHF200

200

330

390

80

490

435

17

41

12

32

211

167

NHF210

210

346

410

85

515

455

18

43

12

33

244

193

NHF220

220

362

425

90

535

475

19

45

12

35

281

219

NHF230

230

378

445

95

560

495

19

47

12

37

321

249

NHF240

240

394

465

100

580

515

20

49

12

38

365

282

NHF250

250

410

475

100

605

535

21

51

12

40

412

313

NHF260

260

426

495

105

630

560

22

53

12

42

464

352

NHF270

270

442

515

110

655

580

23

55

12

43

519

394

NHF280

280

458

530

115

675

600

23

57

12

45

579

434

NHF290

290

474

550

120

700

620

24

59

12

46

644

483

NHF300

300

490

565

120

720

640

25

61

12

48

713

528

NHF310

310

506

580

125

750

665

26

63

12

50

786

582

NHF320

320

522

600

130

770

685

27

65

12

51

865

638

NHF330

330

538

620

135

795

705

27

67

12

53

948

700

NHF340

340

554

635

140

815

725

28

69

12

54

1037

759

NHF350

350

570

650

140

840

745

29

71

12

56

1131

823

NHF360

360

586

670

145

835

750

30

73

16

50

1231

878

 

d

D

L

L1

Df

Dc

R

t

n

ds

Mt

Mass

mm

mm

mm

mm

mm

mm

mm

mm

 

mm

kNm

kg

NHF370

370

602

690

150

855

770

31

75

16

51

1337

951

NHF380

380

618

705

155

880

790

31

77

16

53

1448

1026

NHF390

390

634

725

160

900

810

32

79

16

54

1565

1108

NHF400

400

650

740

160

930

835

33

81

16

56

1689

1194

NHF410

410

666

755

165

950

855

34

83

16

57

1819

1277

NHF420

420

682

775

170

975

875

35

85

16

58

1955

1376

NHF430

430

698

795

175

995

895

35

87

16

60

2098

1474

NHF440

440

714

810

180

1571

915

36

89

16

61

2248

1574

NHF450

450

730

825

180

1040

935

37

91

16

63

2405

1674

NHF460

460

746

845

185

1060

955

38

93

16

64

2569

1787

NHF470

470

762

860

190

1085

975

39

95

16

65

2740

1900

NHF480

480

778

880

195

1105

995

39

97

16

67

2918

2571

NHF490

490

794

900

200

1130

1015

40

99

16

68

3105

2156

NHF500

500

810

910

200

1150

1035

41

101

16

70

3299

2267

NHF510

510

826

930

205

1175

1055

42

103

16

71

3501

2411

NHF520

520

842

950

210

1195

1075

43

105

16

72

3711

2554

NHF530

530

858

965

215

1220

1095

43

107

16

74

3929

2698

NHF540

540

874

985

220

1240

1115

44

109

16

75

4155

2852

NHF550

550

890

1000

220

1270

1140

45

111

16

77

4391

3014

NHF560

560

906

1571

225

1290

1160

46

113

16

78

4634

3180

NHF570

570

922

1035

230

1310

1180

47

115

16

79

4887

3338

NHF580

580

938

1055

235

1335

1200

47

117

16

81

5149

3524

NHF590

590

954

1075

240

1355

1220

48

119

16

82

5420

3708

NHF600

600

970

1085

240

1380

1240

49

121

16

84

5700

3877

NHF610

610

986

1105

245

1400

1260

50

123

16

85

5990

4072

NHF620

620

1002

1125

250

1425

1280

51

125

16

86

6289

4284

NHF630

630

1018

1140

255

1445

1300

51

127

16

88

6599

4477

NHF640

640

1034

1160

260

1465

1320

52

129

16

89

6918

4692

NHF650

650

1050

1175

260

1495

1345

53

131

16

91

7247

4917

NHF660

660

1066

1190

265

1515

1365

54

133

16

92

7587

5128

NHF670

670

1082

1210

270

1540

1385

55

135

16

93

7937

5375

NHF680

680

1098

1230

275

1560

1405

55

137

16

95

8298

5618

NHF690

690

1114

1245

280

1585

1425

56

139

16

96

8669

5860

NHF700

700

1130

1260

280

1605

1445

57

141

16

98

9052

6097

 

 

flange coupling

Proper Installation and Alignment of Flange Couplings

Installing and aligning a flange coupling properly is crucial to ensure its optimal performance and to prevent premature wear or failure. Here are the steps to follow for a successful installation:

  1. Prepare the Components: Before starting the installation, ensure that all the components, including the flange coupling, shafts, and fasteners, are clean and free from dirt or debris. Inspect the coupling for any visible damage or defects.
  2. Check Shaft Alignment: Verify the alignment of the shafts before installing the flange coupling. Misalignment can lead to increased stresses on the coupling and other connected equipment.
  3. Use Proper Lubrication: Apply the recommended lubricant to the contact surfaces of the flange coupling. Proper lubrication reduces friction and wear, enhancing the coupling’s lifespan.
  4. Align the Flange Coupling: Position the flange coupling between the shafts and ensure that the bolt holes are aligned with the corresponding holes in the shafts.
  5. Insert Fasteners: Insert the bolts or screws through the bolt holes and hand-tighten them. Avoid fully tightening any fasteners at this stage.
  6. Check Runout: Measure the runout of the coupling during rotation to verify that it is within acceptable limits. Excessive runout indicates a misaligned coupling.
  7. Properly Torque Fasteners: Using a torque wrench, tighten the fasteners in a cross-pattern to the manufacturer’s recommended torque values. This ensures even distribution of the load and prevents distortion of the flange coupling.
  8. Recheck Alignment: After torquing the fasteners, recheck the shaft alignment to ensure it has not shifted during the tightening process.
  9. Inspect the Assembly: Conduct a final visual inspection of the installed flange coupling and surrounding components to verify that everything is properly aligned and secured.
  10. Perform Test Run: Run the equipment with the newly installed flange coupling under no-load conditions initially to check for any unusual vibrations or noises.
  11. Monitor Performance: During the initial operation and throughout regular use, monitor the flange coupling’s performance and check for signs of wear, misalignment, or other issues.

Professional Installation: If you are unsure about the installation process or need to install a flange coupling in a complex system, consider seeking assistance from a qualified professional or coupling manufacturer’s technical support team. Proper installation is essential for ensuring the long-term reliability and performance of the flange coupling and the connected equipment.

flange coupling

Can Flange Couplings Be Used in Food Processing and Pharmaceutical Industries?

Yes, flange couplings can be used in food processing and pharmaceutical industries, provided they meet certain requirements and standards to ensure hygiene and product safety. These industries have stringent regulations and guidelines to prevent contamination and maintain the quality and purity of their products. When selecting flange couplings for such applications, several considerations must be taken into account:

  • Material Selection: The flange coupling material must be food-grade or pharmaceutical-grade and comply with industry-specific regulations. Stainless steel, particularly austenitic grades like 316L, is commonly used due to its excellent corrosion resistance and ease of cleaning.
  • Hygienic Design: Flange couplings for these industries should have a hygienic design that minimizes crevices, dead spaces, and surface roughness where bacteria or contaminants could accumulate. Smooth surfaces and seamless construction help facilitate thorough cleaning and sterilization.
  • Sealing and Lubrication: Proper sealing is essential to prevent any potential leaks or ingress of contaminants. Food-grade or pharmaceutical-grade lubricants should be used to ensure that there is no risk of contamination from the coupling’s lubrication.
  • Certifications and Compliance: Flange couplings intended for use in food processing and pharmaceutical industries should have relevant certifications, such as FDA (U.S. Food and Drug Administration) approval, EU regulations (e.g., EC No. 1935/2004), and compliance with industry standards like 3-A Sanitary Standards.
  • Cleanability: Flange couplings should be designed for easy disassembly and cleaning to maintain the required hygiene standards. This may involve quick-release or tool-less designs that allow for frequent inspection and cleaning without impeding production processes.
  • Resistant to Corrosive Cleaning Agents: In food processing and pharmaceutical industries, aggressive cleaning agents may be used. The flange coupling material should be resistant to these substances to avoid degradation and maintain the coupling’s integrity over time.

By meeting these criteria, flange couplings can be safely used in food processing and pharmaceutical applications without compromising product quality or safety. It is crucial to work with reputable manufacturers or suppliers who understand the specific requirements of these industries and can provide couplings that adhere to the necessary standards.

flange coupling

Selecting the Appropriate Flange Coupling for a Specific Application

Choosing the right flange coupling for a particular application involves considering several key factors to ensure optimal performance and reliability. Here’s a step-by-step guide to the selection process:

  1. 1. Identify Application Requirements: Understand the specific requirements of the application, including torque, speed, and operating conditions. Determine if the coupling will be exposed to harsh environments, extreme temperatures, or corrosive substances.
  2. 2. Calculate Torque and Power: Calculate the torque and power requirements for the shaft connection. This involves evaluating the motor or engine’s output torque and ensuring the selected coupling can handle the transmitted power.
  3. 3. Consider Misalignment: Assess the level of misalignment that may occur between the shafts during operation. For applications with significant misalignment, consider using flexible flange couplings that can accommodate angular, parallel, and axial misalignment.
  4. 4. Evaluate Speed and RPM: Determine the rotational speed (RPM) at which the coupling will operate. High-speed applications may require a balanced or precision-designed flange coupling to minimize vibrations and prevent damage to connected equipment.
  5. 5. Check Space Constraints: Consider the available space for installing the coupling. Some flange coupling designs may require more space than others, so ensure that the selected coupling fits within the available area.
  6. 6. Review Environmental Conditions: Evaluate the environmental conditions in which the coupling will operate. If the application involves exposure to dust, dirt, or moisture, consider using a protected or sealed flange coupling to prevent contamination.
  7. 7. Determine Flexibility: Decide on the level of flexibility required. Flexible flange couplings are suitable for applications where there may be shaft misalignment or torsional vibration. Rigid flange couplings, on the other hand, are ideal for precision applications with minimal misalignment.
  8. 8. Check Material Compatibility: Ensure that the material of the flange coupling is compatible with the shafts and the operating environment. Consider factors such as corrosion resistance, temperature tolerance, and mechanical properties.
  9. 9. Seek Expert Advice: When in doubt, consult with coupling manufacturers or engineering experts to help you select the most suitable flange coupling for your specific application.

By carefully considering these factors, you can select the appropriate flange coupling that meets the performance and operational requirements of your application, leading to a reliable and efficient shaft connection.

China Best Sales Nhf130 Hydraulic Safety Coupling with Flange  flange couplingChina Best Sales Nhf130 Hydraulic Safety Coupling with Flange  flange coupling
editor by CX 2023-09-30

flexible flange coupling

As one of leading flexible flange coupling manufacturers, suppliers and exporters of products, We offer flexible flange coupling and many other products.

Please contact us for details.

Mail:[email protected]

Manufacturer supplier exporter of flexible flange coupling

Recent Posts